You can select various internal sensors as well as up to five external sensors or connectors.
Measured parameter / Measurement/ storage rate
Technical data
Internal
External (according to cable length)
0.20 m
1.00 m
1.60 m
Temperature 1/s to every 12 h
Working range: external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±0.1 °C (-25...+55 °C) ±0.3 °C (-40...+125 °C)
Item no. T9
Error
select
Item no. FT9/020
Error
1 2 3 4 5
select
Item no. FT9/100
Error
1 2 3 4 5
select
Item no. FT9/160
Error
1 2 3 4 5
select
Working range: -55...+125 °C Max. deviation: ±0.5 °C (10...+70 °C) ±2 °C (-55...+125 °C)
only available externally
Item no. FT2/020
Error
1 2 3 4 5
select
Item no. FT2/100
Error
1 2 3 4 5
select
Item no. FT2/160
Error
1 2 3 4 5
select
Connector for thermal element of Type K (without sensor) 4/s* to every 12 h *(1/s in combination with A4 sensor)
Working range: -200...+1350 °C
only available externally
Item no. FT3/020
Error
1 2 3 4 5
select
Item no. FT3/100
Error
1 2 3 4 5
select
Item no. FT3/160
Error
1 2 3 4 5
select
Humidity with integrated temperature 1/s to every 12 h
Working range: 0...100 % rel. humidity external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±2 % rel. humidity (10...80 %, +25 °C) ±3 % rel. humidity (80...100 %, +25 °C)
Item no. H3
Error
select
Item no. FH3/020
Error
1 2 3 4 5
select
Item no. FH3/100
Error
1 2 3 4 5
select
Item no. FH3/160
Error
1 2 3 4 5
select
Air pressure absolute, with integrated temperature Internal: 1/s to every 12 h External: 10/s* to every 12 h *(1/s in combination with A4 sensor)
Working range: 10...2000 mbar absolute external: -40...+85 °C internal: -20...+65 °C Max. deviation: ±2 mbar (1% FS) (750...1100 mbar absolute, +25 °C)
Item no. P5
Error
select
Item no. FP10/020
Error
1 2 3 4 5
select
Item no. FP10/100
Error
1 2 3 4 5
select
Item no. FP10/160
Error
1 2 3 4 5
select
Working range: 0...14 bar absolute -20...+65 °C Max. deviation: ±50 mbar (1% FS) (1...10 bar abs., +25 °C)
Item no. P7
only available on request
Item no. FP7/020
Error
1 2 3 4 5
select
Item no. FP7/100
Error
1 2 3 4 5
select
Item no. FP7/160
Error
1 2 3 4 5
select
Fluid pressure with integrated temperature Internal: 1/s to every 12 h External: 10/s* to every 12 h *(1/s in combination with A4 sensor) Material in contact with media:Stainless Steel AISI 316L (DIN 1.4404 / 1.4435) O-rings: Viton® 70° Sh
Working range: -1000...3000 mbar relative -20...+85 °C Max. deviation: ±30 mbar (1% FS)
only available externally
Item no. FP9/020
Error
1 2 3 4 5
select
Item no. FP9/100
Error
1 2 3 4 5
select
Item no. FP9/160
Error
1 2 3 4 5
select
Working range: 0...3000 mbar absolute -20...+85 °C Max. deviation: ±30 mbar (1% FS)
only available externally
Item no. FP3/020
Error
1 2 3 4 5
select
Item no. FP3/100
Error
1 2 3 4 5
select
Item no. FP3/160
Error
1 2 3 4 5
select
Working range: 0...30 bar absolute -20...+85 °C Max. deviation: ±0.3 bar (1% FS)
only available externally
Item no. FP4/020
Error
1 2 3 4 5
select
Item no. FP4/100
Error
1 2 3 4 5
select
Item no. FP4/160
Error
1 2 3 4 5
select
Working range: 0...400 bar absolute -20...+85 °C Max. deviation: ±4 bar (1% FS)
only available externally
Item no. FP8/020
Error
1 2 3 4 5
select
Item no. FP8/100
Error
1 2 3 4 5
select
Item no. FP8/160
Error
1 2 3 4 5
select
Working range: 0...1000 bar absolute -20...+85 °C Max. deviation: ±10 bar (1% FS)
only available externally
Item no. FP12/020
Error
1 2 3 4 5
select
Item no. FP12/100
Error
1 2 3 4 5
select
Item no. FP12/160
Error
1 2 3 4 5
select
3-axis-acceleration (static) 50/s to every 12 h
±15 g -20...+65 °C ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C)
Item no. A
Error
select
Item no. FA/020
Error
select
Item no. FA/100
Error
select
Item no. FA/160
Error
select
3-axis-acceleration with Fast Peak (1 kHz) 50/s to every 12 h
Item no. A4
Error
select
Item no. FA4/020
Error
select
Item no. FA4/100
Error
select
Item no. FA4/160
Error
select
Light 1/s to every 12 h
Working range: 0...83 000 lx Max. sensitivity at 550 nm
Item no. L3
Error
select
Item no. FL3/020
Error
1 2 3 4 5
select
Item no. FL3/100
Error
1 2 3 4 5
select
Item no. FL3/160
Error
1 2 3 4 5
select
Connection for strain gauges
Characteristics:full bridge rated output 1 mV/V bridge voltage 3 V
only available externally
Item no. FD/020
Error
1 2 3 4 5
select
Item no. FD/100
Error
1 2 3 4 5
select
Item no. FD/160
Error
1 2 3 4 5
select
Analogue inputs (resolution: 12 bit) 50/s* to every 12 h *(1/s in combination with A4 sensor)
Input configuration:
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
only available externally
Exxxx/020
Error
select
Exxxx/100
Error
select
Exxxx/160
Error
select
Control terminal
Characteristics:
Alarm output
Input for starting and stopping data recording
3 V voltage output
only available externally
Item no. FY/020
Error
select
Item no. FY/100
Error
select
Item no. FY/160
Error
select